Logger Script
 
 
 
  LIMIT SWITCH BOX ¤Ó SOLENOID VALVE ¤Ó AIR FILTER - REGULATOR ¤Ó SPEED CONTROLLER
 
 
The speed controller is installed on actuators such as cylinders and air motors and controls the operating speed of the actuator by adjusting the flow through the actuator.
 
 
Model FC Series
FC3-8 FC3G-8 FC1-8
Operating Pressure 0.5 ~ 15.3 kgf/§²
Fluids Temperature 5 ~ 60¡É
Operating Temperature -10 ~ 60¡É
No. of Needle Rotations 14 10
Port Size 1/4" PT
 
 
Silencers are designed to attenuate the exhaust noise caused by control of pneumatic lines. In general, silencers are mounted on the exhaust ports of solenoid valve, directional control valves and like, to reduce exhaust noise when direction is changed. This contributes to overall noise reduction in plants.
 
 
Model SL Series
SLW-8A SL-8A
Operating Pressure 0 ~ 10.07 kgf/§²
Fluids Temperature 5 ~ 60¡É
Operating Temperature -10 ~ 60¡É
Noise 20dB
Port Size 1/4" PT
Material Plastic Metal